    I have ste this up before, but I only want to set up my EZFlora to run a pump on zone 8. My EZFlora recently broke and I had to replace it.

    I am a Mac guy and run parallels. I have an ISY device controlling the house. The ISY will not reconfigure the EZFlora and I can’t figure out how to get the SimpleHomeNet Utility set up to configure the EZFlora.

    Can anyone help me please?
    Thanks in advance.

    Anonymous
    Inactive
    Post count: 1001

    The Simplehomenet Utility Suite runs on Windows XP. I have tested it successfully on Vista 32 bit. Invoke Simplehomenet Utility Suite.exe. On the initial screen select either PLM, PLC or EZSrve as the powerline interface. Once connected to one of these devices click on the EZFlora tab. Enter the Insteon address of the EZFlora in the Insteon ID field. When connected to the EZFlora the firmware level will display under the Insteon address field. In the Configuration section, click on Zone 8 is a Pump.

    Anonymous
    Inactive
    Post count: 1001

    If you have the capability to issue Insteon commands with some forum of software the command to make Zone 8 Pump Control is cmd1=0x40 cmd2=0x07

    Anonymous
    Inactive
    Post count: 3

    utilility is crashing upon launch. I am running it in a virtual environment under windows xp.

    Anonymous
    Inactive
    Post count: 1001

    Is any error information provided, error messages, etc? The first screen does not appear before the crash?

    There are various objects the program needs to reference on start up. They should have unzipped into the same directory along with the .exe.