AnonymousInactiveMarch 19, 2011 at 3:19 pmPost count: 4
I want to use the unit to sense the status of two garage doors.
I understand how to wire it up to contact switches .. but now I want to use HomeSeer and X10 to sense and control the status.
I need to understand how to set up I1 and I2 to a house code of “K” and what unit # I1 and I2 would be (I do not see it in the material provided with the unit.
tanx.. Don
AnonymousInactiveMarch 19, 2011 at 9:07 pmPost count: 1001The EZIOxx Inputs send Insteon Group messages or Insteon Broadcast messages when state changes occur. They do not send X10 messages.
The output relays can be controlled with Insteon or X10 messages. The EZIO2X4 Quick Start Guide describes the Set button sequence to establish the X10 House code and enable X10 control of the relays. Unit 1 controls relay 1 and Unit 2 controls relay 2.
AnonymousInactiveMarch 19, 2011 at 9:27 pmPost count: 4Thanks for the response ..
If I understand your response, then the only solution is to create an Insteon device .. as the “I1” or “I2” facilities will not have an equivalent X10 status .. so you will not see if I1 goes on or off ..
Correct?
Don
AnonymousInactiveMarch 19, 2011 at 10:03 pmPost count: 1001There is no X10 message associated with an Input changing state.
Define an Insteon device and link Input 1 and Input 2 to the powerline controller used by Homeseer. If done with the Set button process the EZIO2X4 Input is a Controller and the powerline controller is a Responder. When done with the Set button the EZIO2X4 configuration is done automatically. Input 1 state change generates a Group 1 On/Off. Input 2 state change generates a Group 2 On/Off.
I’m not familiar with Homeseer. It may have a method to do the linking and EZIO2X4 configuration.
AnonymousInactiveMarch 20, 2011 at 4:32 pmPost count: 4I have various Insteon devices .. but to be honest, I have defaulted them to X10 protocol (for consistency) .. however I will try this .. If I am having problems setting them up .. (forget about the HomeSeer aspect) who do I call.
Thanks for your help.
Don
AnonymousInactiveMarch 20, 2011 at 5:23 pmPost count: 1001I copied this from their Contacts web page
Support: support@SimpleHomeNet.com
Phone: 877-495-0144 or 949-429-3303
Fax: 949-429-8053Hours of operation: Monday-Friday – 9AM – 5PM PST
I’ll be happy to try and answer any specific questions you may have until they open on Monday.
AnonymousInactiveMarch 21, 2011 at 2:30 pmPost count: 4Thanks .. unfortunately the we had to leave the site .. and will return next weekend .. thanks for your interest and your help .. Don
-